Sign In | Join Free | My enlightcorp.com |
|
Brand Name : HeJin
Certification : Third party calibration certificate(cost additional)
Place of Origin : China
MOQ : 1 Set
Price : Negotiatable
Payment Terms : T/T, L/C
Supply Ability : 3 set per 3 month
Delivery Time : 90 days
Packaging Details : Plywood
test sample : Evaporator/condenser
Vacuum chamber qty. : 2 (customize)
Tracer leak detection gas : Helium
Alarm leak rate : 2 g / year
Cycle time : 75 seconds / chamber
Helium recovery : Recovery rate ≥98%
control : PLC
Material : Stainless steel and Alluminum
Vacuum Chamber Leak Testing Equipment For Evaporator/Condenser With 2 Chamber
Product information:
The leak detection systems are controlled by a state of the art PLC especially configured to comply with the customer’s process requirements. The PLC allows automatic operation including visual and audio signs, alarms, emergency buttons and automatic data storage. It also allows manual control of the system and modification of process parameters and recipes through the touch screen.
Vacuum helium leak tests can be performed using an “inside-out” or “outside-in” method. In an inside-out vacuum leak test, a part is placed in a sealed chamber and secured. A vacuum pump is then used to remove all the atmosphere from the chamber and part. After a sufficient vacuum is reached, the test cycle begins. Leak Testing Equipment
Specification:
Workpiece | Evaporator/condenser |
Vacuum chamber qty. | 2 (customize) |
High pressure gas for large leak detection (Nitrogen) | 4.5 Mpa (media: R410a) / 0.2 Mpa (media: water), pressure can be adjusted downwards |
Tracer leak detection gas | Helium |
Alarm leak rate | 2 g / year (medium: R410a) / 1 g / year (medium: water) |
Helium pressure of fine leak detection | 2.3 Mpa (media: R410a) / 0.2 Mpa (medium: water), adjustable downward |
Test cycle (Excluding loading & unloading time) | 75 seconds / chamber |
Helium recovery | Recovery rate ≥98%. Leak Testing Equipment |
Barcode / QR code printer | Qualified products will be printed qualified barcode / two-dimensional code, unqualified products will not be printed any marks, (number of sheets can be adjusted) With reserved scanner interface |
Leak hole (3 pieces) | One standard leak hole, two checking leak holes |
Alarm display | The fault is displayed on the touch screen and the main maintenance method of the fault is displayed. |
![]() |
HeJin anti rust Vacuum Chamber Helium Leak Test Machine Images |