60 Times / Min Two Stations Plug Socket Test Equipment For Cord Retention

  • 1
  • 2

Brand Name : HeJin

Model Number : HC9917

Certification : calibration certificate (cost additional)

Place of Origin : China

MOQ : 1 set

Price : Negotiatable

Payment Terms : L/C, T/T

Supply Ability : 10 set /month

Delivery Time : 30 days

Packaging Details : Plywood

Product name : Apparatus for testing cord retention

Working station : one, two stations option

test time : 0-9999, preset

Standard : IEC 60884-1

Test weights : 10N*1, 60N*1, 20N*2

Pull applied time : 1s

Contact Now

Plug Socket Test Equipment For Testing Cord Retention 60 Times/Min

Standard of Apparatus for testing cord retention:

IEC 60884-1 ‘Plugs and socket-outlets for household and similar purposes – Part 1: General requirements’ clause 23.2 and figure 20.

Application of Apparatus for testing cord retention:

Rewirable plugs and rewirable portable socket-outlets shall be provided with a cord anchorage such that the conductors are relieved from strain, including twisting, where they are connected to the terminals and that their covering is protected from abrasion.

Apparatus for testing cord retention is used to check the effectiveness of the retention of the cable by the cord anchorage.

Parameter of Apparatus for testing cord retention:

Power supply AC 220V 50Hz
Test weights 10N*1, 60N*1, 20N*2
Rate of testing 60 times / min
Test times 0-9999, preset. Default 100 times.
Pull

– 50 N if the rated current is 2,5 A,

– 60 N if the rated current is above 2,5 A, but not more than 16 A and the rated voltage is up to and including 250 V,

– 80 N if the rated current is above 2,5 A, but not more than 16 A and the rated voltage is above 250 V,

– 100 N if the rated current greater than 16 A.

Pull applied time 1s without jerks

60 Times / Min Two Stations Plug Socket Test Equipment For Cord Retention


Product Tags:

Two Stations Plug Socket Test Equipment

      

Cord Retention Plug Socket Test Equipment

      
Quality 60 Times / Min Two Stations Plug Socket Test Equipment For Cord Retention for sale

60 Times / Min Two Stations Plug Socket Test Equipment For Cord Retention Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)